ASTM E2316-03e1 - 1.10.2003
 
1. Scope

1.1 This test method is used to determine the amount and particle size distribution curve of particles with diameter 106 micrometers or smaller resulting from the attrition of granular pesticides.

1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statement, see Section .8

 
2. Referenced Documents

CIPAC

Test Method MT 187 The size distribution of the particles with sieve diameter less than 106 m is determined by laser light diffraction using CIPAC Test Method MT 187.

E725-96(2021)

Standard Test Method for Sampling Granular Carriers and Granular Pesticides

E11-22

Standard Specification for Woven Wire Test Sieve Cloth and Test Sieves