ASTM E2472-06e1 - 15.6.2006
 
1. Scope

1.1 This standard covers the determination of the resistance to stable crack extension in metallic materials in terms of the critical crack-tip-opening angle (CTOAc), c and/or the crack-opening displacement (COD), 5 resistance curve (). This method applies specifically to fatigue pre-cracked specimens that exhibit low constraint (crack-length-to-thickness and un-cracked ligament-to-thickness ratios greater than or equal to 4) and that are tested under slowly increasing remote applied displacement. The recommended specimens are the compact-tension, C(T), and middle-crack-tension, M(T), specimens. The fracture resistance determined in accordance with this standard is measured as c (critical CTOA value) and/or 5 (critical COD resistance curve) as a function of crack extension. Both fracture resistance parameters are characterized using either a single-specimen or multiple-specimen procedures. These fracture quantities are determined under the opening mode (Mode I) of loading. Influences of environment and rapid loading rates are not covered in this standard, but the user must be aware of the effects that the loading rate and laboratory environment may have on the fracture behavior of the material.

1.2 Materials that are evaluated by this standard are not limited by strength, thickness, or toughness, if the crack-length-to-thickness (a/B) ratio and the ligament-to-thickness (b/B) ratio are greater than or equal to 4, which ensures relatively low and similar global crack-front constraint for both the C(T) and M(T) specimens (, ).

1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses (English) are for information purposes only.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

E399-23

Standard Test Method for Linear-Elastic Plane-Strain Fracture Toughness of Metallic Materials

E561-23

Standard Test Method for KR Curve Determination

E647-23a

Standard Test Method for Measurement of Fatigue Crack Growth Rates (Includes all amendments and changes 6/27/2023).

E1290-08

Standard Test Method for Crack-Tip Opening Displacement (CTOD) Fracture Toughness Measurement

E4-21

Standard Practices for Force Calibration and Verification of Testing Machines

E1823-23

Standard Terminology Relating to Fatigue and Fracture Testing

E2309-05

Standard Practices for Verification of Displacement Measuring Systems and Devices Used in Material Testing Machines

ISO 22889:2007

Metallic Materials--Method of Test for the Determination of Resistance to Stable Crack Extension Using Specimens of Low Constraint

ISO 12135

Metallic Materials--Unified Method of Test for the Determination of Quasistatic Fracture Toughness

E8/E8M-24

Standard Test Methods for Tension Testing of Metallic Materials

E1820-23b

Standard Test Method for Measurement of Fracture Toughness (Includes all amendments and changes 7/14/2023).