ASTM D3497-79(2003) - 26.10.1979
 
Significance and Use

The values of dynamic modulus can be used for both asphalt paving mixture design and asphalt pavement thickness design.

 
1. Scope

1.1 This test method covers procedures for preparing and testing asphalt mixtures to determine dynamic modulus values. The procedure described covers a range of both temperature and loading frequency. The minimum recommended test series consists of testing at 41, 77, and 104°F (5, 25, and 40°C) at loading frequencies of 1, 4, and 16 Hz for each temperature.

1.2 This method is applicable to asphalt paving mixtures similar to mixes 3A, 4A, 5A, 6A, and 7A, as defined by Specification D 3515.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

C617-10

Standard Practice for Capping Cylindrical Concrete Specimens

D3496-99

Standard Practice for Preparation of Bituminous Mixture Specimens for Dynamic Modulus Testing

D3515-01

Standard Specification for Hot-Mixed, Hot-Laid Bituminous Paving Mixtures (Withdrawn 2009)