1. Scope

1.1 This test method covers the determination of pentane insolubles for particles exceeding 0.8 μm in new and used lubricating oils.

Note 1—Pentane insolubles with particle sizes less than 0.8 μm may be studied with appropriate size membrane filters. Particle sizes above or below 0.8 μm can be studied. The precision of this test method has been determined only at 0.8 μm.

1.2 The values stated in SI units are to be regarded as the standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazards statements, see 7.1, 8.2.1, and Annex A1.

 
2. Referenced Documents

D4057-22

Standard Practice for Manual Sampling of Petroleum and Petroleum Products

D4177-22e1

Standard Practice for Automatic Sampling of Petroleum and Petroleum Products (Includes all amendments and changes 3/24/2023).

D4175-24e2

Standard Terminology Relating to Petroleum Products, Liquid Fuels, and Lubricants (Includes all amendments and changes 6/9/2026).