ASTM D4189-95(2002) - 15.5.1995
 
1. Scope

1.1 This test method covers the determination of the silt density index (SDI) of water. This test method can be used to indicate the quantity of particulate matter in water and is applicable to relatively low (1.0 NTU) turbidity waters such as well water, filtered water, or clarified effluent samples. Since the size, shape, and nature of particulate matter in water may vary, this test method is not an absolute measurement of the quantity of particulate matter.

1.2 This test method is not applicable for reagent grade water Types I, II, and III of Specification D 1193, or effluents from most reverse osmosis and ultrafiltration systems.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

E1-14(2025)

Standard Specification for ASTM Liquid-in-Glass Thermometers

D1193-24

Standard Specification for Reagent Water

D1129-24

Standard Terminology Relating to Water

D3370-25

Standard Practices for Sampling Water from Flowing Process Streams