ASTM D69-12 - 1.4.2012
 
Significance and Use

In most applications, a friction tape must have adequate adhesion to remain in place and function properly.

 
1. Scope

1.1 These test methods cover the methods and procedures for testing friction tapes. Such tapes consist of a woven fabric sheeting that has been impregnated with an adhesive insulating compound and cut into rolls of narrow width. These tapes are commonly used for protecting and binding in place, insulation applied to joints of electrical wires and cables, and for other mechanical purposes.

Note 1—The material specifications formerly included in these test methods are now contained in Specification D4514.

1.2 The test methods included in this standard are as follows:

Sections

Adhesion

6-11

Aged Adhesion

12-17

Breaking Strength

18-23

Dielectric Breakdown Voltage

24-29

Dimensions

30-35

Discoloration of Copper

36-40

Parallelism

41-45

1.3 The values stated in inch-pound units are the standard. The SI units in parentheses are for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Note 2—There is no equivalent IEC standard.

 
2. Referenced Documents

D149-25

Standard Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials at Commercial Power Frequencies

D412-16(2021)

Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension

D1711-26

Standard Terminology Relating to Electrical Insulation

D4514-12

Standard Specification for Friction Tape (Withdrawn 2020)

D5423-23

Standard Specification for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation

D6054-97

Standard Practice for Conditioning Electrical Insulating Materials for Testing