ASTM D7353-07 - 1.5.2007
 
Significance and Use

This practice can be used in sampling drums, tanks, and similar containers and in sampling monitoring and waste wells including small diameter (1 in.) wells. The pump can collect samples from multiple depths. The samples can be high-viscosity fluids, aggressive and corrosive fluids, high-purity solutions and abrasive fluids. The pump can be used to mix samples (see D 6063).

Peristaltic pumps use a vacuum to transport the samples. This vacuum may cause some degassing and loss of volatile organic compounds (VOCs) from the sample. When precise quantitative data for VOCs and dissolved gases are not required, peristaltic pumps may be used.

The pump is self-priming, runs dry without damage, and is completely isolated from the pumped fluid. A sample can be taken on the intake or discharge side of the pump.

Some additional advantages of the peristaltic pump are: decontamination of the pump motor is not necessary and the tubing in the pump is disposable and easy to replace. The pumps can be easily started and stopped and can pump fluids at a wide range of pressures and flow rates.

The place, quality and quantity, frequency, and time of sampling is dependent upon the decisions that are to be made (see D 6250), sampling design (see D 6311), the sample, the heterogeneity of the samples (see D 5956), how representative the sample is (see D 6044), and the parameters to be tested as determined by the data quality objectives (DQOs) (see D 5792).

 
1. Scope

1.1 This practice covers the use of a peristaltic pump for sampling liquids from multiple depths. It is applicable for a wide range of fluids including: high-viscosity fluids, aggressive and corrosive fluids, high-purity solutions and abrasive fluids. It is especially useful for sampling liquids that require complete isolation from the pump.

1.2 This practice includes the determination of sample depth, pump set up and collecting a sample to be analyzed.

1.3 This practice is not intended to give detailed instructions for running a peristaltic pump or recommend which peristaltic pump to purchase. It instructs the field personnel how to connect the pump and collect a sample.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

D5681-23

Standard Terminology for Waste and Waste Management

D6634-01

Standard Guide for the Selection of Purging and Sampling Devices for Ground-Water Monitoring Wells

D4687-14(2022)

Standard Guide for General Planning of Waste Sampling

D4448-01(2019)

Standard Guide for Sampling Ground-Water Monitoring Wells

D6311-98(2022)

Standard Guide for Generation of Environmental Data Related to Waste Management Activities: Selection and Optimization of Sampling Design

D6250-98

Standard Practice for Derivation of Decision Point and Confidence Limit for Statistical Testing of Mean Concentration in Waste Management Decisions

D6232-21

Standard Guide for Selection of Sampling Equipment for Waste and Contaminated Media Data Collection Activities

D6063-11(2018)

Standard Guide for Sampling of Drums and Similar Containers by Field Personnel

D6044-21

Standard Guide for Representative Sampling for Management of Waste and Contaminated Media

D5956-21

Standard Guide for Sampling Strategies for Heterogeneous Wastes

D5792-10(2023)

Standard Practice for Generation of Environmental Data Related to Waste Management Activities: Development of Data Quality Objectives

D4840-99(2018)e1

Standard Guide for Sample Chain-of-Custody Procedures (Includes all amendments and changes 8/22/2018).