ASTM D876-09 - 1.10.2009
 
Significance and Use

These test methods include most of the test methods that are considered important to characterize nonrigid vinyl chloride polymer tubing. While they were developed initially for this type of extruded tubing, their use is not limited to this type of tubing.

Variations in these test methods or alternate contemporary methods may be used to determine the values for the properties in this standard provided such methods ensure quality levels and measurement accuracy equal to or better than those prescribed herein. It is the responsibility of the organizations using alternate test methods to be able to demonstrate this condition. In cases of dispute, the test methods specified herein shall be used.

Note 2—Provision for alternate methods is necessary because of (1) the desire to simplify procedures for specific applications without altering the result, and (2) the desire to eliminate redundant testing and use data generated during manufacturing process control, including that generated under Statistical Process Control (SPC) conditions, using equipment and methods other than those specified herein. An example would be the use of laser micrometers or optical comparators to measure dimensions.

 
1. Scope

1.1 These test methods cover the testing of general-purpose (Grade A), low-temperature (Grade B), and high-temperature (Grade C) nonrigid vinyl chloride polymer tubing, or its copolymers with other materials, for use as electrical insulation. For the purpose of these test methods nonrigid tubing shall be tubing having an initial elongation in excess of 100 % at break.

Note 1—These test methods are similar but not identical to those in IEC 606842.

1.2 The values stated in inch-pound units are to be regarded as standard, except for temperature, which shall be expressed in degrees Celsius. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.3 The procedures appear in the following sections:


Procedure


Section

ASTM Reference Standard

Brittleness Temperature

43-45

D746

Corrosion Tests

74-85

D1000

Dielectric Breakdown Voltage at High Humidity

65-73

E104

Dielectric Breakdown Voltage

58-64

D149

Dimensional Tests

8-14

D374

Effect of Elevated Temperatures

25-36

D412

Flammability Test

15-21

Oil Resistance Test

35-42

D471

Penetration Test

46-51

Sampling

6

Strain Relief Test

68-73

Tension Test

22-24

D412

Test Conditions

7

Volume Resistivity

52-57

D257

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 5.

1.5 For fire test caveats, see Section 15.

15.1 This is a fire-test-response standard. The test procedure described measures the resistance of the tubing to ignition or the spread of flame after ignition when tested under the specified conditions.

15.2 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.

15.3 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.

25.1 The effect of elevated temperature is indicated by the changes in ultimate elongation and weight caused by exposure of the tubing to elevated temperatures for a specified time under controlled conditions of air circulation.

 
2. Referenced Documents

D149-25

Standard Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials at Commercial Power Frequencies

E176-24a

Standard Terminology of Fire Standards (Includes all amendments and changes 12/9/2024).

E104-20a

Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Solutions (Includes all amendments and changes 12/21/2020).

D5032-19

Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Glycerin Solutions

D1711-25a

Standard Terminology Relating to Electrical Insulation (Includes all amendments and changes 12/12/2025).

D1000-24

Standard Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications

D746-24

Standard Test Method for Brittleness Temperature of Plastics and Elastomers by Impact

D471-16a(2021)

Standard Test Method for Rubber Property—Effect of Liquids (Includes all amendments and changes 6/25/2021).

D412-16(2021)

Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension

D257-14(2021)e1

Standard Test Methods for DC Resistance or Conductance of Insulating Materials (Includes all amendments and changes 5/6/2021).

D374-99

Standard Test Methods for Thickness of Solid Electrical Insulation

60684–2

Flexible insulating sleeving, Part 2, Methods of test Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http://www.ansi.org.