ASTM D904-99 - 10.10.1999
 
1. Scope

1.1 This practice covers the basic principles and operating procedures for ultraviolet (UV) light aging (with or without water) of adhesive bonded joints having at least one glass or transparent adhered, using fluorescent UV (see Method A) or xenon-arc light sources (see Method B).

1.2 This practice is limited to the apparatus for obtaining, measuring, and controlling the aging conditions, and to the procedures for exposure. Sample preparation, strength, test conditions, and evaluation of the results are described in other ASTM test methods or specifications.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

G151-26

Standard Practice for Exposing Materials in Accelerated Test Devices that Use Laboratory Light Sources

D907-15(2023)

Standard Terminology of Adhesives

G155-25

Standard Practice for Operating Xenon Arc Lamp Apparatus for Exposure of Materials

G154-23

Standard Practice for Operating Fluorescent Ultraviolet (UV) Lamp Apparatus for Exposure of Materials