ASTM E1007-04e1 - 1.4.2004
 
1. Scope

1.1 This test method covers the measurement of the transmission of impact sound generated by a standard tapping machine through floor-ceiling assemblies and associated supporting structures in field situations.

1.2 Measurements may be conducted on all types of floor-ceiling assemblies, including those with floating-floor or suspended ceiling elements, or both, and floor-ceiling assemblies surfaced with any type of floor-surfacing or floor-covering materials.

1.3 This test method further prescribes:

1.3.1 A uniform procedure for reporting test data, that is, the normalized one-third octave band sound pressure levels generated in the receiving room by the operation of the standard tapping machine on the floor-ceiling assembly.

1.3.2 The use of a single-figure classification rating, "Field Impact Insulation Class, FIIC" that can be used by architects, builders, and specification and code authorities for acoustical evaluation purposes in completed buildings. The FIIC is obtained by matching a standard reference contour to the plotted normalized one-third octave band sound pressure levels at each test frequency obtained in accordance with 8.2. For details regarding the derivation and significance of the FIIC, see Classification E989.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

S1.40

S1.11

Electroacoustics - Sound Level Meters Part 1:Specifications

of Sound Insulation in Buildings and of Building Elements; Part VILaboratory Measurement of Impact Sound Insulation of Floors, and Part VIIField Measurements of Impact Sound Insulation of Floors

S1.43

E989-21

Standard Classification for Determination of Single-Number Metrics for Impact Noise

E966-18a

Standard Guide for Field Measurements of Airborne Sound Attenuation of Building Facades and Facade Elements (Includes all amendments and changes 11/28/2018).

E492-25

Standard Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-Ceiling Assemblies Using the Tapping Machine

E336-25a

Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings (Includes all amendments and changes 2/3/2026).

C634-22

Standard Terminology Relating to Building and Environmental Acoustics

E90-23

Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements

E2235-04(2020)

Standard Test Method for Determination of Decay Rates for Use in Sound Insulation Test Methods

E1414-06

Standard Test Method for Airborne Sound Attenuation Between Rooms Sharing a Common Ceiling Plenum