1. Scope

1.1 This fire-test-response standard covers the measurement of the relative fire characteristics of roof coverings under simulated fire originating outside the building. It is applicable to roof coverings intended for installation on either combustible or noncombustible decks when applied as intended for use. The following test methods are included:

1.1.1 Intermittent flame exposure test.

1.1.2 Spread of flame test.

1.1.3 Burning brand test.

1.1.4 Flying brand test.

1.1.5 Rain test.

1.2 Three classes of fire test exposure are described:

1.2.1 Class A Tests are applicable to roof coverings that are effective against severe test exposure, afford a high degree of fire protection to the roof deck, do not slip from position, and do not present a flying brand hazard.

1.2.2 Class B Tests are applicable to roof coverings that are effective against moderate test exposure, afford a moderate degree of fire protection to the roof deck, do not slip from position, and do not present a flying brand hazard.

1.2.3 Class C Tests are applicable to roof coverings that are effective against light test exposure, afford a light degree of fire protection to the roof deck, do not slip from position, and do not present a flying brand hazard.

1.3 The values stated in inch-pound units shall be regarded as the standard. Values given in brackets are for information only.

1.4 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled laboratory conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products or assemblies under actual fire conditions.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.5 The text of this standard references notes and footnotes that provide explanatory information. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of this standard.

 
2. Referenced Documents

D2178-04

Standard Specification for Asphalt Glass Felt Used in Roofing and Waterproofing (Withdrawn 2013)

D225-07

Standard Specification for Asphalt Shingles (Organic Felt) Surfaced With Mineral Granules (Withdrawn 2012)

D4444-25

Standard Test Method for Laboratory Standardization and Calibration of Hand-Held Moisture Meters

D4442-20(2025)

Standard Test Methods for Direct Moisture Content Measurement of Wood and Wood-Based Materials

D3462-09

Standard Specification for Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules

D2626-04

Standard Specification for Asphalt-Saturated and Coated Organic Felt Base Sheet Used in Roofing

D226-06

Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing

D1227-13

Standard Specification for Emulsified Asphalt Used as a Protective Coating for Roofing

D450-07

Standard Specification for Coal-Tar Pitch Used in Roofing, Dampproofing, and Waterproofing

D312-00

Standard Specification for Asphalt Used in Roofing

D227-03

Standard Specification for Coal-Tar-Saturated Organic Felt Used in Roofing and Waterproofing

D2898-10(2024)

Standard Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing

D3158-83

Specification for Asphalt Saturated and Coated Organic Felt Used in Roofing (Withdrawn 1983)

D3018-03

Standard Specification for Class A Asphalt Shingles Surfaced with Mineral Granules

D3378-82A

Specification for Asphalt-Saturated and Coated Asbestos Felt Base Sheet Used in Roofing (Withdrawn 1985)