ASTM E1085-95(2000) - 1.1.2000
 
1. Scope

1.1 This test method covers the wavelength dispersive X-ray spectrometric analysis of low-alloy steels for the following elements:
ElementConcentration Range, %
Nickel 0.04 to 3.0
Chromium0.04 to 2.5
Manganese0.04 to 2.5
Silicon 0.06 to 1.5
Molybdenum0.005 to 1.5
Copper 0.03 to 0.6
Vanadium0.012 to 0.6
Cobalt 0.03 to 0.2
Sulfur 0.009 to 0.1
Niobium 0.002 to 0.1
Phosphorus0.010 to 0.08
Calcium 0.001 to 0.007

1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 10.

 
2. Referenced Documents

E2857-22

Standard Guide for Validating Analytical Methods

E29-22

Standard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications

E1361-02(2026)

Standard Guide for Correction of Interelement Effects in X-Ray Spectrometric Analysis

E1621-22

Standard Guide for Elemental Analysis by Wavelength Dispersive X-Ray Fluorescence Spectrometry

E135-26

Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials

E691-23

Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method