ASTM E1233-00 - 10.6.2000
 
1. Scope

1.1 This test method describes the determination of the structural performance of exterior windows, curtain walls, and doors under cyclic static air pressure differential, using a test chamber. This test method is applicable to all curtain wall assemblies, including, but not limited to, metal, glass, masonry, and stone components.

1.2 This test method is intended only for evaluating the structural performance associated with the specified test specimen, and not the structural performance of adjacent construction.

1.3 Procedure A shall be used when a load-deflection curve is not required for the maximum test loads.

1.4 Procedure B shall be used when a load-deflection curve is required for the maximum test loads.

1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 7.

 
2. Referenced Documents

E998-19

Standard Test Method for Structural Performance of Architectural Glass Products Under the Influence of Uniform Static Loads

E997-15(2021)

Standard Test Method for Evaluating Glass Breakage Probability Under the Influence of Uniform Static Loads by Proof Load Testing

E1300-16

Standard Practice for Determining Load Resistance of Glass in Buildings

E1886-19

Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials

E1996-23

Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes

E631-15

Standard Terminology of Building Constructions

E330-02

Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference