ASTM E1351-01 - 10.12.2001
 
1. Scope

1.1 This practice covers recognized methods for the preparation and evaluation of cellulose acetate or plastic film replicas which have been obtained from metallographically prepared surfaces. It is designed for the evaluation of the metallographic replica to ensure that all significant features of a metallographically prepared surface have been duplicated and preserved on the replica with sufficient detail to permit both LM and SEM examination with optimum resolution and sensitivity.

1.2 This practice may be used as a controlling document in commercial situations.

1.3 The values stated in SI units are to be regarded as the standard. Inch-pound units given in parentheses are for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

E407-23

Standard Practice for Microetching Metals and Alloys

E7-22

Standard Terminology Relating to Metallography

E3-11(2017)

Standard Guide for Preparation of Metallographic Specimens

A335/A335M-23

Standard Specification for Seamless Ferritic Alloy-Steel Pipe for High-Temperature Service