ASTM E1362-99 - 10.10.1999
 
1. Scope

1.1 This test method covers calibration and characterization of secondary terrestrial photovoltaic reference cells to a desired reference spectral irradiance distribution. The recommended physical requirements for these reference cells are described in Specification E1040. Reference cells are principally used in the determination of the electrical performance of a photovoltaic device.

1.2 Secondary reference cells are calibrated indoors using simulated sunlight or outdoors in natural sunlight by reference to a primary reference cell previously calibrated to the same desired reference spectral irradiance distribution.

1.3 This test method applies only to the calibration of a photovoltaic cell that demonstrates a linear short-circuit current versus irradiance characteristic over its intended range of use, as defined in Test Method E1143.

1.4 This test method applies only to the calibration of a photovoltaic cell that has been fabricated using a single photovoltaic junction.

1.5 There is no similar or equivalent ISO standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

E1143-05(2019)

Standard Test Method for Determining the Linearity of a Photovoltaic Device Parameter with Respect To a Test Parameter

E1125-16(2020)

Standard Test Method for Calibration of Primary Non-Concentrator Terrestrial Photovoltaic Reference Cells Using a Tabular Spectrum

E1040-10(2020)

Standard Specification for Physical Characteristics of Nonconcentrator Terrestrial Photovoltaic Reference Cells

E1021-15(2019)

Standard Test Method for Spectral Responsivity Measurements of Photovoltaic Devices

E973-16(2020)

Standard Test Method for Determination of the Spectral Mismatch Parameter Between a Photovoltaic Device and a Photovoltaic Reference Cell

E948-16(2020)

Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight

E927-19

Standard Classification for Solar Simulators for Electrical Performance Testing of Photovoltaic Devices

E816-15(2023)

Standard Test Method for Calibration of Pyrheliometers by Comparison to Reference Pyrheliometers

E772-15(2021)

Standard Terminology of Solar Energy Conversion

E691-23

Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method

E490-22

Standard Solar Constant and Zero Air Mass Solar Spectral Irradiance Tables

G173-23

Standard Tables for Reference Solar Spectral Irradiances: Direct Normal and Hemispherical on 37? Tilted Surface