ASTM E1433-04 - 1.8.2004
 
Significance and Use

Each current standard under the jurisdiction of Committee E33 on Environmental Acoustics is listed, divided into sections under the jurisdiction of the various subcommittees as follows:

E33.01 on Sound Absorption
E33.02 on Open Plan Spaces
E33.03 on Sound Transmission
E33.04 on Application
E33.05 on Research
E33.06 on International Standards
E33.07 on Definitions and Editorial
E33.08 on Mechanical and Electrical System Noise
E33.09 on Community Noise

The ASTM designation, title, use, result or purpose, and a brief summary of each standard is provided. These give enough explanation about the standard to permit one to understand its application, and to differentiate one standard from another.

Note 1—The sequence of these standards does not indicate their relative importance. The user is encouraged to carefully assess the applicability of standards to a situation and select the documents most suited to the circumstances. Comments given may assist in selecting the standard best suited to a specific need.

DESCRIPTION OF STANDARDS

Top

 
1. Scope

1.1 This guide is intended to assist acoustical consultants, architects, specifiers, and others in understanding ASTM standards in environmental acoustics, so that building specifications and other documents can accurately refer to relevant standards. The full standards are found in alphanumeric order in Volume 04.06 of the Annual Book of ASTM Standards.

1.2 The scope of Committee E33 is: "The development of standards on the characteristics and performance of materials, products, systems, and services relating to the acoustical environment and the promotion of related knowledge." Only standards under the jurisdiction of Committee E33 are included in this guide. Additional standards related to environmental acoustics may be found under the jurisdiction of other ASTM committees.

1.3 None of the discussions herein is sufficiently detailed to substitute for reading the full standard. Only a careful reading of a standard will provide a complete understanding of its function. This guide is specifically NOT to be used as a direct reference in building specifications. Only the original standard gives sufficient information to serve as a specification reference.

 
2. Referenced Documents

E1264-23

Standard Classification for Acoustical Ceiling Products

E1265-04(2021)

Standard Test Method for Measuring Insertion Loss of Pneumatic Exhaust Silencers

C367-05

Standard Test Methods for Strength Properties of Prefabricated Architectural Acoustical Tile or Lay-In Ceiling Panels

C384-04(2022)

Standard Test Method for Impedance and Absorption of Acoustical Materials by Impedance Tube Method

C423-23

Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method

C522-03(2022)

Standard Test Method for Airflow Resistance of Acoustical Materials

C634-22

Standard Terminology Relating to Building and Environmental Acoustics

C635-04

Standard Specification for the Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings

C636-04

Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels

E84-23d

Standard Test Method for Surface Burning Characteristics of Building Materials (Includes all amendments and changes 1/29/2024).

E90-23

Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements

E336-23

Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings

E413-22

Classification for Rating Sound Insulation

E 1704

Guide for Specifying Acoustical Performance of Sound-Isolating Enclosures

E492-22

Standard Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-Ceiling Assemblies Using the Tapping Machine

E497-99

Standard Practice for Installing Sound-Isolating Lightweight Partitions (Withdrawn 2008)

E557-12(2020)

Standard Guide for Architectural Design and Installation Practices for Sound Isolation between Spaces Separated by Operable Partitions

E580-02

Standard Practice for Application of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Requiring Moderate Seismic Restraint

E596-22

Standard Test Method for Laboratory Measurement of Noise Reduction of Sound-Isolating Enclosures

E717-84(1999)

Standard Guide for Preparation of the Accreditation Annex of Acoustical Test Standards (Withdrawn 2008)

E756-05(2023)

Standard Test Method for Measuring Vibration-Damping Properties of Materials

E795-23

Standard Practices for Mounting Test Specimens During Sound Absorption Tests

E966-18a

Standard Guide for Field Measurements of Airborne Sound Attenuation of Building Facades and Facade Elements (Includes all amendments and changes 11/28/2018).

E989-21

Standard Classification for Determination of Single-Number Metrics for Impact Noise

E1007-21

Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures

E1014-12(2021)

Standard Guide for Measurement of Outdoor A-Weighted Sound Levels

E1041-85(1998)

Standard Guide for Measurement of Masking Sound in Open Offices (Withdrawn 2002)

E1042-22

Standard Classification for Acoustically Absorptive Materials Applied by Trowel or Spray

E1050-19

Standard Test Method for Impedance and Absorption of Acoustical Materials Using a Tube, Two Microphones and a Digital Frequency Analysis System

E1110-06(2019)

Standard Classification for Determination of Articulation Class

E1111-07

Standard Test Method for Measuring the Interzone Attenuation of Open Office Components

E1123-86(2023)

Standard Practices for Mounting Test Specimens for Sound Transmission Loss Testing of Naval and Marine Ship Bulkhead Treatment Materials

E1289-08(2022)

Standard Specification for Reference Specimen for Sound Transmission Loss

E1332-22

Standard Classification for Rating Outdoor-Indoor Sound Attenuation

E1374-18e1

Standard Guide for Office Acoustics and Applicable ASTM Standards (Includes all amendments and changes 2/16/2018).

E1375-90(2002)

Standard Test Method for Measuring the Interzone Attenuation of Furniture Panels Used as Acoustical Barriers (Withdrawn 2005)

E1376-90(2002)

Standard Test Method for Measuring the Interzone Attenuation of Sound Reflected by Wall Finishes and Furniture Panels (Withdrawn 2005)

E1408-91(2000)

Standard Test Method for Laboratory Measurement of the Sound Transmission Loss of Door Panels and Door Systems (Withdrawn 2009)

E1414-06

Standard Test Method for Airborne Sound Attenuation Between Rooms Sharing a Common Ceiling Plenum

E1503-22

Standard Test Method for Conducting Outdoor Sound Measurements Using a Statistical Sound Analysis System

E1573-22

Standard Test Method for Measurement and Reporting of Masking Sound Levels Using A-Weighted and One-Third-Octave-Band Sound Pressure Levels

E1574-98(2023)

Standard Test Method for Measurement of Sound in Residential Spaces

E 1686

Guide for Selection of Environmental Noise Measurements and Criteria

E1222-22

Standard Test Method for Laboratory Measurement of the Insertion Loss of Pipe Lagging Systems

E1179-13(2019)

Standard Specification for Sound Sources Used for Testing Open Office Components and Systems

E1130-16(2021)

Standard Test Method for Objective Measurement of Speech Privacy in Open Plan Spaces Using Articulation Index

E1124-10(2016)

Standard Test Method for Field Measurement of Sound Power Level by the Two-Surface Method

E 2202

Practice for Measurements of Equipment-Generated Continuous Noise for Assessment of Health Hazards

E 2179

Test Method for Laboratory Measurement of the Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors2

E 1780

Guide for Measuring Outdoor Sound Received from a Nearby Fixed Source

E 1779

Guide for Preparing a Measurement Plan for Conducting Outdoor Sound Measurements

E477-20

Standard Test Method for Laboratory Measurements of Acoustical and Airflow Performance of Duct Liner Materials and Prefabricated Silencers