ASTM E162-98 - 10.1.2002
 
1. Scope

1.1 This fire-test-response standard, to be used for research and development purposes, covers the measurement of surface flammability of materials. It is not intended for use as a basis of ratings for building code purposes.

1.2 This standard should be used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions and should not be used to describe or appraise the fire-hazard or fire-risk of materials, products, or assemblies under actual fire conditions. However, results of the test may be used as elements of a fire- hazard assessment or a fire-risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard or fire risk of a particular end use.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.4 The values stated in inch-pound units are to be regarded as the standard. The values in parentheses are for information only.

 
2. Referenced Documents

ISO13943

C1186-22e1

Standard Specification for Flat Fiber-Cement Sheets (Includes all amendments and changes 10/10/2023).

E176-24

Standard Terminology of Fire Standards

E1546-21

Standard Guide for Development of Fire-Hazard-Assessment Standards

E84-23d

Standard Test Method for Surface Burning Characteristics of Building Materials (Includes all amendments and changes 1/29/2024).

D3675-22

Standard Test Method for Surface Flammability of Flexible Cellular Materials Using a Radiant Heat Energy Source

C1288-23

Standard Specification for Fiber-Cement Interior Substrate Sheets