ASTM E1784-08 - 15.12.2008
 
Significance and Use

This test method provides for the determination of total peroxide in acrylonitrile in the range of 0.1 to 0.6 ppm. Only peroxides or other oxidants that react under the conditions of this test method are measured.

 
1. Scope

1.1 This test method describes a procedure for determining the total peroxide content of acrylonitrile in the range of 0.1 to 0.6 mg H2O2/kg acrylonitrile (ppm). Peroxides are an undesirable impurity in acrylonitrile.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 7.

1.4 Review the current Material Safety Data Sheets (MSDS) for detailed information concerning toxicity, first aid procedures, and safety precautions.

 
2. Referenced Documents

E180-03

Standard Practice for Determining the Precision of ASTM Methods for Analysis and Testing of Industrial and Specialty Chemicals (Withdrawn 2009)

D1193-06(2018)

Standard Specification for Reagent Water

E60-11(2022)e1

Standard Practice for Analysis of Metals, Ores, and Related Materials by Spectrophotometry (Includes all amendments and changes 6/29/2022).

E200-23

Standard Practice for Preparation, Standardization, and Storage of Standard and Reagent Solutions for Chemical Analysis