ASTM E2022-16 - 1.8.2016
 
Significance and Use

5.1 This practice is intended to provide a method that will yield uniformity of calculations used in making, matching, or controlling colors of objects. This uniformity is accomplished by providing a method for calculation of weighting factors for tristimulus integration consistent with the methods utilized to obtain the weighting factors for common illuminant-observer combinations contained in Practice E308.

5.2 This practice should be utilized by persons desiring to calculate a set of weighting factors for tristimulus integration who have custom source, or illuminant spectral power distributions, or custom observer response functions.

 
1. Scope

1.1 This practice describes the method to be used for calculating tables of weighting factors for tristimulus integration using custom spectral power distributions of illuminants or sources, or custom color-matching functions.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to its use.

 
2. Referenced Documents

CIEStandard S002

E2729-16(2021)

Standard Practice for Rectification of Spectrophotometric Bandpass Differences

E284-22

Standard Terminology of Appearance

E308-22

Standard Practice for Computing the Colors of Objects by Using the CIE System