ASTM E2115-19 - 1.11.2019
 
Significance and Use

5.1 This guide is intended to help prevent lead poisoning of children by providing standardized procedures for conducting a lead hazard assessment and providing information needed to develop and recommend lead hazard control options as described in Practice E2252.

5.2 This guide is applicable for use in either occupied or unoccupied dwellings and in other child-occupied facilities.

5.3 The procedures in this guide, when supplemented by recommendations for controlling lead hazards, provide for the conduct of a lead risk assessment of a dwelling or of other child-occupied facilities.

5.4 This guide may be used to supplement assessment procedures used to determine the causes of elevated blood lead (EBL) levels in young children.

Note 2: In cases of EBL levels, investigation of the total living environment of the child and a pediatric medical evaluation may also be needed. Reference should be made to documents such as Managing Elevated Blood Lead Levels Among Young Children,6 Preventing Lead Poisoning in Young Children (1991),7 the HUD Guidelines, and Screening Young Children for Lead Poisoning (1997).7

5.5 Although this guide was developed for dwellings and for other child-occupied facilities, this guide may be suitable for lead hazard assessments in non-residential buildings and other properties following agreement between assessor and client on appropriate lead action levels.

5.6 This guide is not intended for use in identifying building materials that when abraded or otherwise degraded, such as that which may occur in remodeling or renovation activities, may result in lead hazards.

5.7 Lead hazard assessment reports describe lead hazards identified at the time the assessment was performed. The locations, types, or severities of lead hazards can change over time as a result of property improvement or deterioration, significant changes in property use, or other factors.

Note 3: The term “lead-free” should never be used to describe the absence of lead hazards because testing methodologies are not designed to measure the total absence of lead. Small amounts of lead present in building materials and components or soil may result in a hazard with changes in building conditions or as a result of activities that create dust that contains lead.

5.8 This guide is applicable for assisting professionals, homeowners, owners or occupants of rental property, lenders, insurers, and others with a property interest in determining the presence of lead hazards.

5.9 This guide also is applicable for assisting designers of lead hazard mitigation projects to target resources toward lead hazard controls that are deemed most likely to result in the prevention of lead poisoning in young children.

 
1. Scope

1.1 This guide covers how to conduct, document, and report findings of a lead hazard assessment of dwellings and of other child-occupied facilities.

1.2 Procedures for assessment of personal items, such as toys, dishes, and hobby materials that may contribute to elevated lead levels in blood are not included in this guide.

1.3 Procedures for random sampling of units within dwellings having multiple units are not included.

1.4 This guide contains notes, which are explanatory, and are not part of the mandatory requirements of this guide.

1.5 The values stated in SI units are to be regarded as the standard.

1.5.1 Exception—The inch-pound and SI units shown for wipe sampling data are to be individually regarded as standard for wipe sampling data.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

 
2. Referenced Documents

Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing,

2nd Edition, July 2012 (HUD Guidelines) Available from U.S. Department of Housing and Urban Development (HUD), 451 7th Street, SW, Washington DC 20410, http://www.hud.gov.

E1727-20

Standard Practice for Field Collection of Soil Samples for Subsequent Lead Determination

E1728-16

Standard Practice for Collection of Settled Dust Samples Using Wipe Sampling Methods for Subsequent Lead Determination

E1729-20

Standard Practice for Field Collection of Dried Paint Samples for Subsequent Lead Determination

E1753-22

Standard Practice for Use of Qualitative Chemical Spot Test Kits for Detection of Lead in Dry Paint Films

E1979-21

Standard Practice for Ultrasonic Extraction of Paint, Dust, Soil, and Air Samples for Subsequent Determination of Lead

E2051-01

Standard Practice for the Determination of Lead in Paint, Settled Dust, Soil and Air Particulate by Field-Portable Electroanalysis (Withdrawn 2010)

E2119-20

Standard Practice for Quality Systems for Conducting In Situ Measurements of Lead Content in Paint or Other Coatings Using Field-Portable X-Ray Fluorescence (XRF) Devices

E2239-20

Standard Practice for Record Keeping and Record Preservation for Lead Hazard Activities

E2252-22

Standard Practice for Selection of Lead Hazard Reduction Methods for Identified Risks in Residential Housing or Child Occupied Facilities

E2255/E2255M-22

Standard Practice for Conducting Visual Assessments for Lead Hazards in Buildings

40 CFR 745,

Environmental Protection Agency (EPA), Lead-Based Paint Poisoning Prevention in Certain Residential Structures (especially subparts D, L and Q) Available from U.S. Government Publishing Office, 732 N. Capitol St., NW, Washington, DC 20401-0001, http://www.gpo.gov.

E1726-21

Standard Practice for Preparation of Soil Samples by Hotplate Digestion for Subsequent Lead Analysis

E631-15

Standard Terminology of Building Constructions

E1605-22

Standard Terminology Relating to Lead in Buildings

E1613-12

Standard Test Method for Determination of Lead by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES), Flame Atomic Absorption Spectrometry (FAAS), or Graphite Furnace Atomic Absorption Spectrometry (GFAAS) Techniques (Withdrawn 2021)

D4840-99(2018)e1

Standard Guide for Sample Chain-of-Custody Procedures (Includes all amendments and changes 8/22/2018).

E1644-21

Standard Practice for Hot Plate Digestion of Dust Wipe Samples for the Determination of Lead

E1645-21

Standard Practice for Preparation of Dried Paint Samples by Hotplate or Microwave Digestion for Subsequent Lead Analysis