ASTM E2322-03 - 1.10.2003
 
Significance and Use

Transverse LoadThe procedures outlined will serve to evaluate the performance of floor and roof segments for deflection, permanent set and ultimate capacity. Performance criteria based on data from these procedures can ensure structural adequacy and effective service.

Concentrated LoadThis concentrated load test shall be used to evaluate surface indentation of structural framing members.

These procedures will serve to evaluate performance of roof and floor segments under simulated service conditions. Diaphragm shear loading of roof and floor segments shall be evaluated under Method E 455. Impact loading shall be evaluated under Test Methods E 661 or E 695.

 
1. Scope

1.1 These test methods cover the following procedures for determining the structural properties of segments of floor and roof constructions:

SectionTest SpecimensLoadingDeformation MeasurementsReportPrecision and BiasTesting FloorsTransverse LoadConcentrated LoadTesting RoofsTransverse LoadConcentrated Load

1.2 Metric units (SI) are to be considered as the primary standard units.

1.3 These test methods serve to evaluate the performance of floors and roofs panels subjected to (1) Uniform loading, and (2) Concentrated static loading, which represent conditions sustained in the actual performance of the element. The standard is not intended for the evaluation of individual structural framing and/or supporting members (floor joist, rafters and trusses).

1.4 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of the standard.

1.5 This standard is not intended to cover concrete floor slabs.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

E196-06(2018)

Standard Practice for Gravity Load Testing of Floors and Low Slope Roofs

E455-19

Standard Test Method for Static Load Testing of Framed Floor or Roof Diaphragm Constructions for Buildings

E695-22

Standard Test Method of Measuring Relative Resistance of Wall, Floor, and Roof Construction to Impact Loading

E661-22

Standard Test Method for Performance of Wood and Wood-Based Floor and Roof Sheathing Under Concentrated Static and Impact Loads

E1592-05(2017)

Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference

E631-15

Standard Terminology of Building Constructions

E575-05(2018)

Standard Practice for Reporting Data from Structural Tests of Building Constructions, Elements, Connections, and Assemblies

E73-13(2021)

Standard Practice for Static Load Testing of Truss Assemblies

E72-22

Standard Test Methods of Conducting Strength Tests of Panels for Building Construction

E4-21

Standard Practices for Force Calibration and Verification of Testing Machines

C109/C109M-23

Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 50?mm [2 in.] Cube Specimens)