ASTM E247-01(2005) - 1.5.2005
 
Significance and Use

This test method is intended to be used for compliance with compositional specifications for silica content. It is assumed that all who use these procedures will be trained analysts capable of performing common laboratory procedures skillfully and safely. It is expected that work will be performed in a properly equipped laboratory and that proper waste disposal procedures will be followed. Appropriate quality control practices must be followed such as those described in Guide E 882.

 
1. Scope

1.1 This test method covers the determination of silica in iron ores, iron ore concentrates and agglomerates, and manganese ore in the concentration range from 0.5 to 15 %.

1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user oi this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

E877-21

Standard Practice for Sampling and Sample Preparation of Iron Ores and Related Materials for Determination of Chemical Composition and Physical Properties

D1193-06(2018)

Standard Specification for Reagent Water

E691-23

Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method

E135-23a

Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials (Includes all amendments and changes 7/17/2023).

E50-17

Standard Practices for Apparatus, Reagents, and Safety Considerations for Chemical Analysis of Metals, Ores, and Related Materials

E882-10(2016)e1

Standard Guide for Accountability and Quality Control in the Chemical Analysis Laboratory (Includes all amendments and changes 10/27/2017).