ASTM E2594-09 - 15.3.2009
 
Significance and Use

This test method for the chemical analysis of nickel alloys is primarily intended to test material for compliance with specifications such as those under jurisdiction of ASTM Committee B02. It may also be used to test compliance with other specifications that are compatible with the test method.

It is assumed that all who use this test method will be trained analysts capable of performing common laboratory procedures skillfully and safely, and that the work will be performed in a properly equipped laboratory.

This is a performance-based test method that relies more on the demonstrated quality of the test result than on strict adherence to specific procedural steps. It is expected that laboratories using this test method will prepare their own work instructions. These work instructions will include detailed operating instructions for the specific laboratory, the specific reference materials employed, and performance acceptance criteria. It is also expected that, when applicable, each laboratory will participate in proficiency test programs, such as described in Practice E 2027, and that the results from the participating laboratory will be satisfactory.

 
1. Scope

1.1 This test method describes the inductively coupled plasma atomic emission spectrometric analysis of nickel alloys, such as specified by Committee B02, and having chemical compositions within the following limits:

ElementApplication
Range (%)

Aluminum

0.011.00

Boron

0.0010.050

Calcium

0.0010.05

Carbon

0.100.20

Chromium

0.0133.0

Cobalt

0.1020.0

Copper

0.013.00

Iron

0.0150.0

Lead

0.0010.01

Magnesium

0.00010.100

Manganese

0.013.0

Molybdenum

0.0130.0

Niobium

0.016.0

Nickel

25.080.0

Nitrogen

0.0010.20

Oxygen

0.00010.003

Phosphorous

0.0010.030

Sulfur

0.00010.010

Silicon

0.011.50

Tantalum

0.0050.10

Tin

0.0010.020

Titanium

0.0016.0

Tungsten

0.015.0

Vanadium

0.011.0

Zirconium

0.010.10

1.2 The following elements may be determined using this test method. The test method user should carefully evaluate the precision and bias statements of this test method to determine applicability of the test method for the intended use.

ElementQuantification
Range (%)

Aluminum

0.0601.40

Boron

0.0020.020

Calcium

0.0010.003

Copper

0.0100.52

Magnesium

0.0010.10

Manganese

0.0020.65

Niobium

0.0205.5

Phosphorous

0.0040.030

Tantalum

0.0100.050

Tin

0.0020.018

Titanium

0.0203.1

Tungsten

0.0070.11

Vanadium

0.0100.50

Zirconium

0.0020.10

1.3 This test method has only been interlaboratory tested for the elements and ranges specified. It may be possible to extend this test method to other elements or different concentration ranges provided that method validation is performed that includes evaluation of method sensitivity, precision, and bias as described in this document. Additionally, the validation study must evaluate the acceptability of sample preparation methodology using reference materials or spike recoveries, or both. The user is cautioned to carefully evaluate the validation data against the laboratorys data quality objectives. Method validation of scope extensions is also a requirement of ISO/IEC 17025.

1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific warning statements are given in 8.2.6.3 and safety hazard statements are given in Section 9.

 
2. Referenced Documents

D1193-06(2018)

Standard Specification for Reagent Water

E50-17

Standard Practices for Apparatus, Reagents, and Safety Considerations for Chemical Analysis of Metals, Ores, and Related Materials

E55-23

Standard Practice for Sampling Wrought Nonferrous Metals and Alloys for Determination of Chemical Composition

E88-11(2017)

Standard Practice for Sampling Nonferrous Metals and Alloys in Cast Form for Determination of Chemical Composition

E135-23a

Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials (Includes all amendments and changes 7/17/2023).

E1329-10

Standard Practice for Verification and Use of Control Charts in Spectrochemical Analysis (Withdrawn 2019)

E1479-16

Standard Practice for Describing and Specifying Inductively Coupled Plasma Atomic Emission Spectrometers

E2027-17

Standard Practice for Conducting Proficiency Tests in the Chemical Analysis of Metals, Ores, and Related Materials

ISO/IEC?17025

General Requirements for the Competence of Calibration and Testing Laboratories

ISO?Guide?31

Reference Materials--Contents of Certificates and Labels

ISO?Guide?34

General Requirements for the Competence of Reference Material Producers

ISO?Guide?98-3

Uncertainty of Measurement Part 3: Guide to the Expression of Uncertainty in Measurement (GUM:1995), First Edition

E1601-19