ASTM E308-99 - 10.8.2001
 
1. Scope

1.1 This practice provides the values and practical computation procedures needed to obtain CIE tristimulus values from spectral reflectance, transmittance, or radiance data for object-color specimens.

1.2 Procedures and tables of standard values are given for computing from spectral measurements the CIE tristimulus values X, Y, Z, and chromaticity coordinates x, y for the CIE 1931 standard observer and X10, Y10, Z 10 and x10. y10 for the CIE 1964 supplementary standard observer.

1.3 Standard values are included for the spectral power of six CIE standard illuminants and three CIE recommended fluorescent illuminants.

1.4 Procedures are included for cases in which data are available only in more limited wavelength ranges than those recommended, or for a measurement interval wider than that recommended by the CIE. This practice is applicable to spectral data obtained according to Practice E 1164 with 1-, 5-, 10-, or 20-nm measurement interval.

1.5 Procedures are included for cases in which the spectral data are, and those in which they are not, corrected for bandpass dependence. For the uncorrected cases, it is assumed that the spectral bandpass of the instrument used to obtain the data was approximately equal to the measurement interval and was triangular in shape. These choices are believed to correspond to the most widely used industrial practice.

1.6 This practice includes procedures for conversion of results to color spaces that are part of the CIE system, such as CIELAB and CIELUV (3). Equations for calculating color differences in these and other systems are given in Test Method D 2244.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

ISO Standard 11664-2:2007(E)/CIE S 014-2/E:2006

Colorimetric Illuminants,

D2244-23

Standard Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates

E284-22

Standard Terminology of Appearance

E313-20

Standard Practice for Calculating Yellowness and Whiteness Indices from Instrumentally Measured Color Coordinates

E1164-23

Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation

E2022-16(2021)

Standard Practice for Calculation of Weighting Factors for Tristimulus Integration

E2729-16(2021)

Standard Practice for Rectification of Spectrophotometric Bandpass Differences

PH2.23

Lighting Conditions for Viewing Photographic Color Prints and Transparencies Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http://www.ansi.org.

ISO Standard 11664-1:2007(E)/CIE S 013-1/E:2006

Standard Colorimetric Observers, Available from CIE (International Commission on Illumination), http://www.cie.co.at

CIE Standard D?001

Colorimetric Illuminants and Observers (Disk)

Computer disk containing Tables?5 and 6 Computer disk of 72 tables is available from ASTM Headquarters. Request Adjunct No. . Originally approved in 1994.