ASTM E463-09 - 1.5.2009
 
Significance and Use

This test method is intended as a referee method for compliance with compositional specifications for impurity content. It is assumed that all who use this procedure will be trained analysts capable of performing common laboratory practices skillfully and safely. It is expected that work will be performed in a properly equipped laboratory and that proper waste disposal procedures will be followed. Follow appropriate quality control practices such as those described in Guide E 882.

 
1. Scope

1.1 This test method covers the determination of silica in fluorspar in concentrations from 0.5 % to 10 %.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

E882-10(2016)e1

Standard Guide for Accountability and Quality Control in the Chemical Analysis Laboratory (Includes all amendments and changes 10/27/2017).

E276-21

Standard Test Method for Particle Size or Screen Analysis at 4.75 mm (No. 4) Sieve and Finer for Metal-Bearing Ores and Related Materials

E135-23a

Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials (Includes all amendments and changes 7/17/2023).

E50-17

Standard Practices for Apparatus, Reagents, and Safety Considerations for Chemical Analysis of Metals, Ores, and Related Materials

D1193-06(2018)

Standard Specification for Reagent Water