ASTM E515-95(2000) - 10.5.2000
 
1. Scope

1.1 This test method covers procedures for detecting or locating leaks, or both, by bubble emission techniques. A quantitative measure is not practical. The normal limit of sensitivity for this test method is 4.5 X 10 -10 mol/s (1 X 10 -5 Std cm /s).

1.2 Two techniques are described:

1.2.1 Immersion technique, and

1.2.2 Liquid application technique.

Note-Additional information is available in ASME Boiler and Pressure Vessel Code, Section V, Article 10-Leak Testing, and Guide E479.

1.3 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

E479-91(2000)

Standard Guide for Preparation of a Leak Testing Specification

E543-21

Standard Specification for Agencies Performing Nondestructive Testing

E1316-24

Standard Terminology for Nondestructive Examinations

MIL-L-25567D

Leak Detection Compound Oxygen Systems Available from Standardization Documents Order Desk, DODSSP, Bldg. 4, Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http://dodssp.daps.dla.mil.

NAS-410

Certification and Qualification of Nondestructive Test Personnel Available from Aerospace Industries Association of America, Inc. (AIA), 1000 Wilson Blvd., Suite 1700, Arlington, VA 22209-3928, http://www.aia-aerospace.org.