1. Scope

1.1 This test method covers determination of the diagonal tensile or shear strength of 1.2 by 1.2-m (4 by 4-ft) masonry assemblages by loading them in compression along one diagonal (see Fig. 1), thus causing a diagonal tension failure with the specimen splitting apart parallel to the direction of load.

1.2 Annex A1 provides suggestions regarding the determination of the diagonal-tension strength of masonry under combined diagonal-tension and compressive loading.

1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are provided for information only.

1.4 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

C140-13

Standard Test Methods for Sampling and Testing Concrete Masonry Units and Related Units

E575-05(2018)

Standard Practice for Reporting Data from Structural Tests of Building Constructions, Elements, Connections, and Assemblies

E4-21

Standard Practices for Force Calibration and Verification of Testing Machines

C109/C109M-23

Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 50?mm [2 in.] Cube Specimens)

C67-17

Standard Test Methods for Sampling and Testing Brick and Structural Clay Tile

C1019-20

Standard Test Method for Sampling and Testing Grout for Masonry