ASTM E949-88(1996) - 1.1.1996
 
1. Scope

1.1 This test method covers the measurement of the total moisture in RDF as it exists at the time it is sampled. Because of its empirical nature, strict adherence to test procedures are required for valid results. The standard is available to producers, vendors, and consumers as a total, two-stage moisture method.

1.2 Since RDF can vary from extremely wet (water saturated) to relatively dry, special emphasis must be placed on sampling, sample preparation, and the method of determination.

1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For hazard statement, see Section 7.

 
2. Referenced Documents

D3173-11

Standard Test Method for Moisture in the Analysis Sample of Coal and Coke

E829-23

Standard Practice for Preparing Refuse-Derived Fuel (RDF) Laboratory Samples for Analysis

E790-21

Standard Test Method for Residual Moisture in Refuse-Derived Fuel Analysis Samples