ASTM F1334-11 - 1.11.2011
 
Significance and Use

The test results enable the comparison of A-weighted sound emission from vacuum cleaners when tested under the condition of this test method.

 
1. Scope

1.1 This test method calculates the overall A-weighted sound power level emitted by small portable upright, canister, combination vacuum cleaners, and central vacuum cleaner motorized nozzles intended for operation in domestic and commercial applications.

1.1.1 To determine the Sound Power Level of a central vacuum at the power unit location refer to Test Method F 2544.

1.2 A-weighted sound pressure measurements are performed on a stationary vacuum cleaner in a semi-reverberant room. This test method determines sound power by a comparison method for small noise sources, that is, comparison to a broadband reference sound source.

1.3 This test method describes a procedure for determining the approximate A-weighted sound power level of small noise sources. This test method uses a non-special semi-reverberant room.

1.4 Results are expressed as A-weighted sound power level in decibels (referenced to one picowatt).

1.5 The values stated in inch-pound units are to be regarded as the standard. The values in parentheses are for information only.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

ANSI S1.43

Specifications for Integrating-Averaging Sound Level Meters

ANSI S1.10

Method for the Calibration of Microphones

F2607-08(2022)

Standard Test Method for Measuring the Hard Surface Floor-Cleaning Ability of Household/Commercial Vacuum Cleaners

F2544-11(2018)

Standard Test Method for Determining A-Weighted Sound Power Level of Central Vacuum Power Units

F655-13

Standard Specification for Test Carpets and Pads for Vacuum Cleaner Testing (Withdrawn 2022)

ANSI S12.51/ISO 3741

Acoustics - Determination of sound power levels of noise sources using sound pressure - Precision methods for reverberation rooms

E691-23

Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method

E177-20

Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods

C634-22

Standard Terminology Relating to Building and Environmental Acoustics

ANSI S12.53/ISO 3743

Acoustics - Determination of sound power levels of noise sources - Engineering methods for small, movable sources in reverberant fields

ANSI S12.57/ISO 3747

Standard Acoustics - Determination of sound power levels of noise sources using sound pressure - Comparison method in situ

F608-24

Standard Test Method for Evaluation of Carpet Embedded Dirt Removal Effectiveness of Household/Commercial Vacuum Cleaners