ASTM F1365-91(1999)e1 - 10.4.1999
 
1. Scope

1.1 This test method covers the determination of the water infiltration resistance of gasketed plastic underground conduit joints using a pressurized water bladder apparatus.

1.2 The values stated in inch-pound units are to be regarded as the standard. The SI values in parentheses are provided for information only.

1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

D618-21

Standard Practice for Conditioning Plastics for Testing

F512-19(2024)

Standard Specification for Smooth-Wall Poly(Vinyl Chloride) (PVC) Conduit and Fittings for Underground Installation

UL?651

Schedule 40 and 80 Rigid PVC Conduit Available from Underwriters Laboratories (UL), 333 Pfingsten Rd., Northbrook, IL 60062-2096, http://www.ul.com.

TC-2

Electrical Plastic Tubing (EPT) and Conduit (EPC-40 and EPC-80) Available from National Electrical Manufacturers Association (NEMA), 1300 N. 17th St., Suite 1752, Rosslyn, VA 22209, http://www.nema.org.

TC-6

PVC and ABS Plastic Utilities Duct for Underground Installation

TC-8

Extra-Strength PVC Plastic Utilities Duct for Underground Installation

D2122-22

Standard Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings