ASTM F1930-15 - 1.2.2015
 
Significance and Use

5.1 Use this test method to measure the thermal protection provided by different materials, garments, clothing ensembles, and systems when exposed to a specified fire (see 3.2.2, 3.2.3, 4.1, and 10.4).

5.1.1 This test method does not simulate high radiant exposures, for example, those found in electric arc flash exposures, some types of fire exposures where liquid or solid fuels are involved, nor exposure to nuclear explosions.

5.2 This test method provides a measurement of garment and clothing ensemble performance on a stationary upright manikin of specified dimensions. This test method is used to provide predicted skin burn injury for a specific garment or protective clothing ensemble when exposed to a laboratory simulation of a fire. It does not establish a pass/fail for material performance.

5.2.1 This test method is not intended to be a quality assurance test. The results do not constitute a material’s performance specification.

5.2.2 The effects of body position and movement are not addressed in this test method.

5.3 The measurement of the thermal protection provided by clothing is complex and dependent on the apparatus and techniques used. It is not practical in a test method of this scope to establish details sufficient to cover all contingencies. Departures from the instructions in this test method have the potential to lead to significantly different test results. Technical knowledge concerning the theory of heat transfer and testing practices is needed to evaluate if, and which departures from the instructions given in this test method are significant. Standardization of the test method reduces, but does not eliminate, the need for such technical knowledge. Report any departures along with the results.

 
1. Scope

1.1 This test method is used to provide predicted human skin burn injury for single layer garments or protective clothing ensembles mounted on a stationary upright instrumented manikin which are then exposed in a laboratory to a simulated fire environment having controlled heat flux, flame distribution, and duration. The average exposure heat flux is 84 kW/m2 (2 cal/s•cm2), with durations up to 20 seconds.

1.2 The visual and physical changes to the single layer garment or protective clothing ensemble are recorded to aid in understanding the overall performance of the garment or protective clothing ensemble and how the predicted human skin burn injury results can be interpreted.

1.3 The skin burn injury prediction is based on a limited number of experiments where the forearms of human subjects were exposed to elevated thermal conditions. This forearm information for skin burn injury is applied uniformly to the entire body of the manikin, except the hands and feet. The hands and feet are not included in the skin burn injury prediction.

1.4 The measurements obtained and observations noted can only apply to the particular garment(s) or ensemble(s) tested using the specified heat flux, flame distribution, and duration.

1.5 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire-hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.

1.6 This method is not a fire-test-response test method.

1.7 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units or other units commonly used for thermal testing. If appropriate, round the non-SI units for convenience.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.9 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.

 
2. Referenced Documents

E2683-17

Standard Test Method for Measuring Heat Flux Using Flush-Mounted Insert Temperature-Gradient Gages

D123-23

Standard Terminology Relating to Textiles

F1494-23

Standard Terminology Relating to Protective Clothing

NFPA 86

Standard for Ovens and Furnaces, 1999 Edition

NFPA 85

Boiler and Combustion Systems Hazards Code, 2007 Edition

NFPA 58

Liquefied Petroleum Gas Code 2008 Edition

NFPA 54

National Fuel Gas Code, 2009 Edition

CAN/CGSB-3.14 M88

Liquefied Petroleum Gas (Propane)

CAN/CGSB-4.2 No. 58-M90

Textile Test Methods Colorfastness and Dimensional Change in Domestic Laundering of Textiles

Test Method 158

Dimensional Changes on Dry-Cleaning in Perchloroethylene: Machine Method

D1835-22

Standard Specification for Liquefied Petroleum (LP) Gases

E691-23

Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method

E511-07(2020)

Standard Test Method for Measuring Heat Flux Using a Copper-Constantan Circular Foil, Heat-Flux Transducer

E457-08(2020)

Standard Test Method for Measuring Heat-Transfer Rate Using a Thermal Capacitance (Slug) Calorimeter

E177-20

Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods

D5219-15

Standard Terminology Relating to Body Dimensions for Apparel Sizing

D3776/D3776M-20

Standard Test Methods for Mass Per Unit Area (Weight) of Fabric

Test Method 135

Dimensional Changes of Fabrics after Home Laundering