ASTM F2072-01(2007) - 1.2.2007 | ||||||||
Significance and Use | ||||||||
The presence of water inside a membrane switch can affect its mechanical operation or electrical functionality, or both. This practice establishes a procedure to verify the ability of a membrane switch to resist the entry of liquid into itself or a finished product, or both. It is useful in identifying design deficiencies. Hosedown testing may be destructive, therefore any samples tested should be considered unfit for future use. | ||||||||
1. Scope | ||||||||
1.1 This practice establishes procedures for the hosedown of a membrane switch to verify adequate protection from ingress of water from a high-volume water spray. 1.2 This practice can also be used to verify the ability of a membrane switch or graphics layer to act as a liquid seal for a finished product. 1.3 Additional test methods or practices can be incorporated to investigate specific results or capabilities. 1.4 This practice is a modification of NEMA Publication Number 250-1991 Section 6.7 which is a test for hosedown of a finished product housing. | ||||||||
2. Referenced Documents | ||||||||
|