ASTM F2476-05 - 1.5.2005
 
Significance and Use

Carbon dioxide gas transmission rate (CO2TR) is an important determinant of the packaging protection afforded by barrier materials. It is not, however, the sole determinant, and additional tests, based on experience, must be used to correlate packaging performance with CO2TR. It is suitable as a referee method of testing, provided that purchaser and seller have agreed on sampling procedures, standardization procedures, test conditions and acceptance criteria.

 
1. Scope

1.1 This method covers a procedure for determination of the steady-state rate of transmission of carbon dioxide gas through plastics in the form of film, sheeting, laminates, coextrusions, or plastic-coated papers or fabrics. It provides for the determination of (1) carbon dioxide gas transmission rate (CO2TR), (2) the permeance of the film to carbon dioxide gas (PCO2) , and (3) carbon dioxide permeability coefficient (P"CO2) in the case of homogeneous materials.

1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

E691-23

Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method

E177-20

Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods

D1898-68(1989)

Standard Practice for Sampling of Plastics (Withdrawn 1998)