1. Scope

1.1 This specification covers performance requirements, test methods, and marking requirements for metric- and inch-sized system components (electrofusion and mechanical fittings) when joined with metric- or inch-sized PEX pipe (Specification F2788) as a system, intended for use up to and including a maximum working temperature of 200°F [93°C ]. The following performance requirements are described for the fittings – 68°F [20°C] hydrostatic strength, 176°F [80°C] hydrostatic strength, short-term internal pressure resistance, resistance to tensile loads, cohesive resistance for electrofusion fittings at both the minimum and maximum recommended temperatures, impact resistance for saddle fittings, and leak tightness and pull out tests for mechanical fittings. The metric- and inch-sized components covered by this specification are intended for the above-ground and buried pressure piping applications, such as industrial & general-purpose pipelines, potable water pipelines, and fire – extinguishing pipelines.

1.2 The text of this specification references notes, footnotes, and appendixes, which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.

1.3 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text the SI units are shown in brackets. The values stated in each system may not be exact equivalents: therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

Note 1: Suggested hydrostatic design stresses and hydrostatic pressure ratings for pipe and fittings are listed in Appendix X1. Design, assembly, and installation considerations are discussed in Appendix X2. An optional performance qualification and an in-plant quality control program are recommended in Appendix X3.

1.4 The following safety hazards caveat pertains only to the test method portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

D1600-18

Standard Terminology for Abbreviated Terms Relating to Plastics (Withdrawn 2024)

ISO 15875-5

Plastic piping systems for hot and cold water installations Crosslinked polyethylene (PE-X) fitness for purpose of the system

PPI TR-4

PPI Listing of Hydrostatic Design Basis (HDB), Strength Design Basis (SDB), Pressure Design Basis (PDB) and Minimum Required Strength (MRS) Ratings for Thermoplastic Piping Materials or Pipe

Standard No. 14

for Plastic Piping Components and Related Materials

NSF/ANSI 61

Drinking Water System Components -- Health Effects

D1898-68(1989)

Standard Practice for Sampling of Plastics (Withdrawn 1998)

F412-23

Standard Terminology Relating to Plastic Piping Systems

F1055-16a(2022)

Standard Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene and Crosslinked Polyethylene (PEX) Pipe and Tubing (Includes all amendments and changes 11/8/2022).

F2788-11

Standard Specification for Metric-sized Crosslinked Polyethylene (PEX) Pipe

Fed Std. No. 123

Marking for Shipment (Civil Agencies)

D2837-22

Standard Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic Pipe Materials or Pressure Design Basis for Thermoplastic Pipe Products

D2749-22

Standard Symbols for Dimensions of Plastic Pipe Fittings

D618-21

Standard Practice for Conditioning Plastics for Testing

MIL-STD-129

Marking for Shipment and Storage

ISO 4427-3

Plastic piping systems Polyethylene (PE) pipes and fittings for water supply fittings

Plastic piping systems Polyethylene (PE) pipes and fittings for water supply fitness for purpose of the system