ASTM F689-97 - 10.10.1997
 
1. Scope

1.1 This practice describes a procedure for the determination of the temperature history of above-ground plastic gas pressure pipe encased in a metallic casing. Such temperature changes may be due to ambient air temperature, or solar exposure, or both.

1.2 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

E220-19

Standard Test Method for Calibration of Thermocouples By Comparison Techniques

D2513-20

Standard Specification for Polyethylene (PE) Gas Pressure Pipe, Tubing, and Fittings

Thermoplastic Fuel Gas Piping/Investigation of Maximum Temperatures Attained by Plastic Pipe Inside Metal Service Risers, TR 30,

Plastic Pipe Institute, May 1978 Available from Plastics Pipe Institute (PPI), 105 Decker Court, Suite 825, Irving, TX 75062, http://www.plasticpipe.org.